Accessories Catalogue
We Manufacture Custom Design Accessories
Wall Boxes Leak-Proof
Wall Boxes Leak-Proof
LSWB-8,LDWB-8,LTWB-8 are all models for single, double and triple leak proof wall boxes. Leak proof wall boxes have an extruded aluminum grille (optional for all sizes).
Wall Boxes - Standard
Wall Boxes - Standard
SWB-8,SWB-12, DWB-8,DWB-12,JWB-4,TWB-8,TWB-12,SFWB are all models for single, double, triple, junior and soffit standard wall boxes. Also an extruded aluminium grille is available for single and double wall boxes.
Wall Boxes-Weather Tight
Wall Boxes - Weather Tight
SWB-8,DWB-8,TWB-8 are all models for single, double and triple wheather tight wall boxes. A single coat of epoxy paint is applied to the interior surface of the box and two coats of epoxy paint applied to the exterior.
Wall Boxes-Super Quiet
Wall Boxes - Super Quiet
EB1-8, EB2-8, EBJ-8, EB3-8, EBS-8, EB-I-8 are all models for super quiet wall boxes.
GB-4, GB-5, GB-6
Balance Boxes
Balance boxes GB-4, GB-5, GB-6
LT-90-44, LT-90-45
Lint Traps
For drywall installation ceiling or wall mounted. LT-90 lint trap has 4 dia. inlet for dryer connection and 5 dia. outlet - model LT-90-45, 4 dia. outlet - model LT-90-44
LT-180, LT-180F
Lint Traps
LT-180 and LT-180F are equipped with filter frame attached to the removable door for easy operation.
LT-250-45
Lint Traps
LT-250-45 equipped with filter frame attached to the removable see-through door for easy operation. It also locks the gasketed door with two latches that makes it totally air tight.
LT-300-44, LT-300-45
Lint Traps
LT-300 lint trap has 4" dia. inlet for dryer connection and 5" dia. outlet for better performance. Also available in 4" dia. outlet. (Specify when ordering) Removable filter unit secured in position with positive lock.
LT-200-44, LT-200-45
Lint Traps
LT-200-45 model is designed For drywall installation ceiling or wall mounted. Model LT-200-45 lint trap has 4" dia. inlet for dryer connection and 5" dia. outlet for better performance. Also available in 4" dia. outlet. (Model LT-200-44)
LT 400 SD
Lint Trap for Stacker Dryer
Simple and quick installation, 38 sq. inch filtering area increases dryer efficiency, Stainless Steel filter screen for long life, Available in 4" & 5" dia. sizes outlet, Viewing Plexiglass, Oven baked finish, Easy to clean, Positive Lock
DAS-200
Dryer Amp Sensor
This sensor can be mounted to an electrical junction box or conveniently located on the fuse/breaker panel. When dryer is started, power passes through the sensor which becomes activated and automatically starts the booster fan.
DAS-250
Dryer Amp Sensor
This controller senses when a clothes dryer is drawing 1.2 AMP of current. When this occurs a relay contact closes turning the dryer vent booster fan "ON". When current drops below the 2 AMP threshold the relay contacts open turning the booster fan "OFF". The sensor is designed to mount in a standard electrical box. The AMP Sensor may be placed in an electrical box adjacent to the junction box in which the wires supplying power to the dryer are located (see back of this page). The dryer supply neutral (white) wire passes through the center of the AMP Sensor donut. No physical connection is made.
DHB-100
Dryer Heat Sensor
Heat sensor unit is installed in the exhaust pipe of the dryer. During dryer operation, heat is produced allowing the sensor to automatically engage the booster fan.
DSC300-240 and DSC300-115
Dryer Starter Control Box
The dryer starter control box is a pre-wired unit with dryer plug for easy and simple installation for the electrician. This control works in conjunction with the booster fan. When booster fan is in ON it will engage power to the starter control box and only then the dryer can be turned ON.
RD 4, 5, 6, 7, 8, 9,10
Back Draft Damper
The back draft damper is round and complete with a spring.
IPBD
Inline Plastic Backdraft Damper
Available sizes 3", 4", 5", & 6" diameter
PBD
Plastic Backdraft Damper
Available sizes 3", 4", 5", & 6" diameter
RCE, RCI
Roof Caps
RCE with a back draft damper and a bird screen is suitable for exhaust fans. It is mounted on flat or pitch roof. RCI with a bird screen is suitable for fresh air intake. It is also mounted on flat or pitch roof.
FCS
Heavy Duty Fresh Air Intake Cap Steel
Sizes 4", 5", 6", 7", 8", 9", 10", 12" dia. - 24 Ga. satin coat black finish steel - Equipped with spring loaded aluminum damper - Bird Screen and special sizes are available upon request
FCA
Heavy Duty Fresh Air Intake Cap Aluminum
Sizes 4", 5", 6", 7", 8", 9", 10", 12" dia. - 0.025" Aluminum - Equipped with removable fly screen - Bird Screen and special sizes are available upon request
ECS
Heavy Duty Exhaust Vent Cap Steel
Sizes 4", 5", 6", 7", 8", 9", 10", 12" dia. - 24 Ga satin coat black finish steel - Equipped with spring loaded aluminum damper - Bird Screen and special sizes are available upon request
ECA
Heavy Duty Exhaust Vent Cap Aluminum
Sizes 4", 5", 6", 7", 8", 9", 10", 12" dia. - 0.025" Aluminum - Equipped with spring loaded aluminum damper - Bird Screen and special sizes are available upon request
WC-310
Heavy Duty Wall Cap
- 24 Ga satin coat black finish steel - Equipped with balance aluminum back draft damper
BV-23
Brick Vent
- 24 Ga satin coat steel - Equipped with fly screen
EC-310
Eaves Cap
- 24 Ga satin coat black finish steel - Equipped with balance aluminium back draft damper and aluminium grille
RJ-40, RJ-60, RJ-1010
Aluminium Roof Jack
4" - RJ-40, base 12" x 12" 6" - RJ-60, base 13 3/4" x 13 3/4" 10" x 10" - RJ-1010, base 18" x 18" - .025" aluminium - Equipped with aluminium damper
RL-80, RL-100
Aluminum Roof Louvers
8" - RL80, base 14" x 18" 10" - RL100, base 16" x 20" - .025" aluminium - Equipped with fly screen
T1517
Time delay switch
Voltage is applied to the unit at all times via the black and white wires. When the switch is placed in the "On" position, power is applied to the Lamp and Fan Output. When the switch is placed in the "Timed" position, the power is removed from the Lamp Output and the Fan Output stays on for the preset delay time. After the delay time the power is removed from the Fan Output. Should the switch be placed in the "On" position during the delay time, the timer will be reset and both outputs will be "On" as defined above. Should power be interrupted, when in the "Timed" position, the timer will be reset and when power is reapplied the Fan Output will be "On" for the preset delay time after the power is re-applied.
RFM-100
Dryer Booster Fan Monitor Light
RFM-100 is installed in series with dryer booster fan. In the event of booster fan failure during operation, the fan monitor light goes "OFF". In this situation, Do Not operate your clothes dryer. Contact your qualified service personel. For more information contact factory.
RH100
RH100 (Humidistat/Dehumidstat )
CVC
Air Volume Controller
The installation of a constant volume control damper in a ventilation system has some advantages compared with other control systems (control register, diaphragm, etc...) System regulation or calibration is not needed The air volume is always the same whatever the pressure variation in the ventilation system.
RF-100
Media Air Cleaner
The high efficiency air cleaner housing is easily installed with any type of forced air heating/cooling system. Standard sheet metal procedures are followed and no special tools are required. The Reversomatic air cleaner housing is mounted in the return air duct - horizontally, vertically, or at an angle as required. Continuous air circulation is recommended for best results. Set the furnace blower to run constantly.
Access Door
FLAT - ADF Series
The "ADF" Series are manufactured from 20 gauge satin coat steel for corrosion resistance and come with a screwdriver operated cam-lock. These doors are featured with round cornered flange invisible hinge and flush mounted door panel. They can be installed on drywall, masonry and tiles surfaces. Custom Sizes, powder coated finishing and various color options are available upon request.
Access Door
PROJECT - ADP Series
The "ADP" Series are manufactured from 20 gauge satin coat steel for corrosion resistance and come with a screwdriver operated cam-lock. These doors are designed to install on drywalls, masonry and tiled surfaces. Custom Sizes, powder coated finishing and various color options are available upon request.
Slab Duct
Air Specialty Duct System
The Air Specialty Duct System is a rectangular seamed duct embedded in the structural concrete floors of high-rise buildings. The primary use of the Air Specialty Duct System is to exhaust air from bathroom fans, range-hoods and clothes dryers. The Air Specialty Duct System can also be used as a general exhaustor fresh air intake. The Air Specialty Duct System is a complete engineered system consisting of a variety of fittings. The ducts are manufactured in standard 5 foot, 8 foot, 10 foot lengths. For special applications, custom lenghts are also available. To download brochure click on "LINKS & RESOURCES".
Copyright (c) 2009 Reversomatic.